Send Message
Xian Sulab Machinery Co., Ltd. 86--15109261813 eric@elevator-spareparts.com
Otis Elevator Lift Drive Inverter OVFR03B-403 ( LRU ) KCA KDA KEA21305ACB5

Otis Elevator Lift Drive Inverter OVFR03B-403 ( LRU ) KCA KDA KEA21305ACB5

  • High Light

    Otis Lift Drive Inverter

    ,

    KDA Elevator Drive Inverter

    ,

    OVFR03B-403 Elevator Inverter

  • Model Number
    OVFR03B-403(LRU) KCA KDA KEA21305ACB5
  • Product Name
    Drive OVFR03B-403(LRU) KCA KDA KEA21305ACB5
  • Delivery Time
    2-3 Working Days
  • Supply Ability
    10000pcs Per Month
  • After-Sale Service
    Online Technical Support
  • Type
    Elevator Parts
  • Suitable For
    Elevator
  • Warranty
    One Year
  • Brand Name
    SULAB
  • Minimum Order Quantity
    1 PC
  • Packaging Details
    Carton
  • Delivery Time
    2-3 working days
  • Payment Terms
    L/C, T/T, Western Union, MoneyGram, Paypal
  • Supply Ability
    10000pcs per month

Otis Elevator Lift Drive Inverter OVFR03B-403 ( LRU ) KCA KDA KEA21305ACB5

Details for Otis Elevator Drive Inverter OVFR03B-403(LRU) KCA KDA KEA21305ACB5

 

Brand SULAB
Description Elevator Inverter
Part No.

OVFR03B-403(LRU)

KEA21305ACB5
MOQ 1PC
Transportion TNT, UPS, DHL, Fedex, Air, Sea
Applicable Elevator
Packages Carton, Wooden case, Pallet etc
Delivery Time Normally 2-3 working days after payment
Warranty One year
Payment Method Company Bank, Western union, alibaba, Paypal, Personal bank etc

 

 

Pictures for Otis Elevator Drive Inverter OVFR03B-403(LRU) KCA KDA KEA21305ACB5

 

Otis Elevator Lift Drive Inverter OVFR03B-403 ( LRU ) KCA KDA KEA21305ACB5 0

 

OVF30 Inverter Fault Code Explanation

D(Q) Current FDBK
An error occurred when the drive started to build up the field current
(1) Check the speed parameters of the inverter; (2) Check whether there is any bad contact or disconnection between the output of the inverter and the motor, including the UDX contact; (3) Replace the XU2, UD3 and LEM boards; (4) , replace the frequency converter
Current FDBK sum DSP
The software detects that the vector sum of the three-phase output current is not 0, and exceeds the parameter INV IO LIMIT
(1), check INV IO LIMIT; (2), check the three-phase output U, V, W insulation; (3), check the connection between VA/VB and XU2 board; (4), replace the XU2 board or LEM board; (5), replace the inverter