Common Troubleshooting
Contact burning/sticking: Measure the main contact resistance (should be ≤50mΩ). If the burning is severe, replace the contact assembly; troubleshoot the causes such as overload and unstable voltage, and check if the arc suppressor is damaged.
Coil burnout: Measure the coil resistance (normally several hundred Ω). Burnout is often caused by overvoltage, incorrect wiring, or frequent switching; replace the coil and check the control circuit protection (such as fuses).
Poor auxiliary contact connection: Test the on/off status of the auxiliary contacts. Clean the contacts or replace the module if there is oxidation or wear, ensuring normal signal transmission.
Abnormal operation (loud noise/failure to engage): Check if the coil voltage meets the specifications, clean the oil and dirt from the core end face, and troubleshoot mechanical jamming or spring fatigue problems.
| Brand | SULAB |
| Description | Elevator parts |
| Model | LC1D32M7C |
| MOQ | 1PC |
| Transportion | TNT, UPS, DHL, Fedex, Air, Sea |
| Applicable | Elevator |
| Packages | Carton, Wooden case, Pallet etc |
| Delivery Time | Normally 2-3 working days after payment |
| Warranty | One year |
| Payment Method | Company Bank, Western union, alibaba, Paypal etc |
Flexible expansion and adaptation: Supports the addition of accessories such as time-delay heads and mechanical interlocks to form time-delay contactors, reversible contactors, or star-delta starters; 50/60Hz universal coil adapts to different power grids, and DIN rail mounting facilitates integration and maintenance.
High reliability and long service life: Mechanical life of up to 20 million cycles, electrical life of up to 1.6 million cycles (AC-3, 32A), suitable for environments from -40℃ to 60℃, and adaptable to demanding working conditions such as elevator machine rooms/shafts.