Send Message
Xian Sulab Machinery Co., Ltd. 86--15109261813 eric@elevator-spareparts.com
OTIS Elevator Lift Circuit Board Main Mother Panel PCB Board MCB3X PCB GCA26800KV4

OTIS Elevator Lift Circuit Board Main Mother Panel PCB Board MCB3X PCB GCA26800KV4

  • High Light

    OTIS Elevator Lift Circuit Board

    ,

    Lift Circuit Board MCB3X

    ,

    Main Mother Panel PCB Board

  • Model Number
    GCA26800KV4 GCA26800KV44
  • Product Name
    PCB Board Panel MCB3X PCB GCA26800KV4
  • Delivery Time
    2-3 Working Days
  • Supply Ability
    1000pcs Per Month
  • After-Sale Service
    Online Technical Support
  • Suitable For
    Elevator
  • Warranty
    One Year
  • Type
    Elevator Parts
  • Brand Name
    OT
  • Minimum Order Quantity
    1 PC
  • Packaging Details
    Carton
  • Delivery Time
    2-3 working days
  • Payment Terms
    L/C, T/T, Western Union, MoneyGram, Paypal
  • Supply Ability
    1000pcs per month

OTIS Elevator Lift Circuit Board Main Mother Panel PCB Board MCB3X PCB GCA26800KV4

 OTIS Elevator Lift Circuit Main Mother PCB Board Panel MCB3X PCB GCA26800KV4


Description of Elevator Lift Circuit PCB Board
 

The Function of Elevator main board 

 

A control system includes light, machine, electricity, and calculation. The main board is mainly responsible for calculation, which is equivalent to the human brain. It collects the running state of the elevator, outputs the corresponding analog signal, and controls the correct and safe operation of the elevator.

 

 

Details for OTIS Elevator Lift Circuit PCB Board Panel MCB3X PCB GCA26800KV4 GCA26800KV44

 

Brand OT
Description Elevator Circuit PCB Board
Part No. GCA26800KV4
MOQ 1PC
Transportion TNT, UPS, DHL, Fedex, Air, Sea
Applicable Elevator
Packages Carton, Wooden case, Pallet etc
Delivery Time Normally 2-3 working days after payment
Warranty One year
Payment Method Company Bank, Western union, alibaba, Paypal, Personal bank etc


Pictures for OTIS Elevator Lift  Circuit PCB Board Panel MCB3X PCB GCA26800KV4 GCA26800KV44
OTIS Elevator Lift Circuit Board Main Mother Panel PCB Board MCB3X PCB GCA26800KV4 0
The reason why the elevator circuit board is burned out,
​​
The parameter setting of the inverter deceleration time is relatively small and the deceleration over voltage self-processing function of the inverter is not used. When the inverter drags a large inertia load, its deceleration time is set relatively small. During the deceleration process, the output frequency of the inverter decreases faster, but the load inertia is relatively large, and the deceleration is relatively slow due to its own resistance, so that the load drags The speed of the motor is higher than the speed corresponding to the frequency output by the inverter, the motor is in the power generation state, and the inverter has no energy processing unit or its function is limited, which leads to the increase of the intermediate DC circuit voltage of the inverter and exceeds the protection value. An over voltage trip fault occurs.​​