5400 elevator fault code
No KSE at stop (NoKSE-STDSTL) Description: The car is located at one end of the hoistway and it is found that the KSE signal does not match the position calculated by the ranging pulse generator. Additional information: no source identification: no possible fault cause: a) parameter value is wrong b) magnet polarity is wrong c) KSE switch should take measures: a) check the placement position of KSE and parameters SHAFT-PARA, KSE-DISTANC and Whether SHAFT-PARA, GAP-LENGTH match. b) Check the magnet polarity, the KSE at the bottom is the south pole, the LSR next to it is the north pole, and the magnet at the top is the south pole. c) Check the KSE switch, check the connection of the KSE switch to the PCB.