Send Message
Xian Sulab Machinery Co., Ltd. 86--15109261813 eric@elevator-spareparts.com
OTIS Elevator PCB Board KCA26800ACC1 KDA26800ACC1 KEA26800ACC1

OTIS Elevator PCB Board KCA26800ACC1 KDA26800ACC1 KEA26800ACC1

  • High Light

    OT OTIS Elevator PCB Board

    ,

    Elevator PCB Board KCA26800ACC1

    ,

    elevator circuit board KDA26800ACC1

  • Model Number
    KCA26800ACC1 KDA26800ACC1 KEA26800ACC1
  • Product Name
    Drive Pcb Board KCA26800ACC1 KDA26800ACC1 KEA26800ACC1
  • Delivery Time
    2-3 Working Days
  • Supply Ability
    1000pcs Per Month
  • After-Sale Service
    Online Technical Support
  • Suitable For
    Elevator
  • Warranty
    One Year
  • Type
    Elevator Parts
  • Brand Name
    OT
  • Minimum Order Quantity
    1 PC
  • Packaging Details
    Carton
  • Delivery Time
    2-3 working days
  • Payment Terms
    L/C, T/T, Western Union, MoneyGram, Paypal
  • Supply Ability
    1000pcs per month

OTIS Elevator PCB Board KCA26800ACC1 KDA26800ACC1 KEA26800ACC1

 

Details for OTIS Elevator Inverter Drive PCB Board KCA26800ACC1 KDA26800ACC1 KEA26800ACC1

 

Brand OT
Description Drive Pcb Board
Part No. KCA26800ACC1 KDA26800ACC1 KEA26800ACC1
MOQ 1PC
Transportion TNT, UPS, DHL, Fedex, Air, Sea
Applicable Elevator
Packages Carton, Wooden case, Pallet etc
Delivery Time Normally 2-3 working days after payment
Warranty One year
Payment Method Company Bank, Western union, alibaba, Paypal, Personal bank etc


Pictures for OTIS Elevator Inverter Drive PCB Board KCA26800ACC1 KDA26800ACC1 KEA26800ACC1

 

OTIS Elevator PCB Board KCA26800ACC1 KDA26800ACC1 KEA26800ACC1 0

 

 

 

OVF30 inverter fault code description
1. Base (GATE SUPPLY) fault
The hardware has detected insufficient voltage in the IGBT gate drive circuit.
(1)check whether the grounding of the inverter is good; 

(2)replace the XU2 board and UD3 board;

(3)replace the inverter
2. Inverter OCT inverter output overcurrent
(1)check the parameters INVTR OCT, DRIVE RTD I RMS, INV IFSCALE;

(2)check whether there is a short circuit or insulation problem on the motor side;

(3)check whether the brake is fully opened;

(4)check the PVT and wiring; (5), replace the inverter
3. IGBT Desatuation/
Problems with IGBT devices and related circuits such as gate drive circuits
(1)replace the base and UD3 board;

(2)replace the inverter